Issue / Question

Customer is not getting the correct scanned data when scanning in Velocity 2.1.1 with a EAN-13 Barcode

Applicable To

Velocity, MC93, 2.1.1, Ivanti, Emulation, Android, Oreo, Wavelink, Scanning, EAN13, symbology

Resolution / Answer

Confirmed that the barcode was EAN-13.  Outside of Velocity, the barcode decode was correct.  Inside of Velocity the decode was not right.

Velocity by default, is set up for EAN-10.  To read the EAN-13 symbology, you will need to change one parameter:
Bring up the Velocity Console.
Select Host and then Scanner.
Highlight your Zebra Scanner Profile and select Edit.
Select UPC/EAN Settings.

Change the default value of ISBN-10 to ISBN-13
选择确定
Select Save:


Select Deploy to create a new .wldep file:


Launch Velocity and test.



 