GPIO Configuration
- This page supports configuring the GPIO-LED control.
- Note: check IOT connector documentaion for help on GPIO-LED configuration.
- Defaults: Specifies the default state of the GPOs and LED.
- GPO1: Specifies the default state of the GPO 1.
- GPO2: Specifies the default state of the GPO 2.
- GPO3: Specifies the default state of the GPO 3.
- GPO4: Specifies the default state of the GPO 4.
- LED3: Specifies the default state of the LED 3.
- Event: Specifies the event of interest.
- Event:Specifies the event of interest.
- Number:Specifies the Port Number of the GPI. This is valid only if Event is selected as GPI.
- State:Specifies the State of the GPI to be monitored. When the GPI goes to the specified state, then the event is trigerred.
This is valid only if the Event is selected as GPI.
- Conditions: Specifies the additional conditions to check for before taking the action on an event.
- Cloud Connected:If checked, the configured action is taken only if the IoT Connector is connected to the endpoints.
- Cloud Disconnected:If checked, the configured action is taken only if the IoT Connector is disconnected from the endpoints.
- Radio Ongoing:If Checked, the configured action is taken only if the reader is currently trying to read tags (Start is issued).
- Radio Notongoing:If Checked, the configured action is taken only if the reader is not trying to read tags (Stop is issued).
- Operand:More than one condition can be specified in which the case operand to apply must also be specified.
If AND Operand is selected, then the action will be applied only if all the conditions specified have been met.
If OR Operand is selected, then if one of the conditions is met, the configured action will be taken.
- Action: The action to be taken.
- Entity:Entity to be controlled when the event occurs.
- State:specifies what state to put the control entity into.
- Post Action State:specifies what State the Entity must be left in after performing the action.
- On:This is part of the blink parameters. Specifies how long in milli-seconds the entity must be in the state configured.
For GPOs and LED the On state is what is configured in State field in Action section.
- Off:This is part of the blink parameters. Specifies how long in milli-seconds the entity must be in the off state.
For GPOs the Off state is the opposite of the state configured in State field in the Action section.
For LED, the Off state is when LED is OFF.
- Blink Duration:Specifies the duration in milli-seconds for which to perform On/Off of the entity.
- Add: Add the current configuration to list of the configurations.
- Save: save configuration to the reader.
- Update: Update the current configuration to list of the configurations.
|