HotFix CFE (Cumulative Fixes from Engineering) Package contains multiple SPR Hotfixes into a single package. The HotFix CFE Package helps the end users to keep up to date with all the SPR hotfixes for given product software release / revision.
HotFix CFE packages are validated only by engineering validation team and the package follows Zebra Technologies HotFix Package Policy.
Description
CFE package CFE_MC55_A0_WM_044710_EN_v010300_e_WB.cab / CFE_MC55_A0_WM_044710_EN_v010300_e_NB.cab file includes the following HotFixes:
SPR No | Synopsis |
---|---|
29109 | Unable to decode RSSEXP barcode using SE960 scan engine. |
29323 | The Device doesn't have a visual indicator when adjusting the general OS volume with side volume keys. |
26402 | Device Fusion/WIFI adapter Keep resetting after connect to WIFI and placed in cradle. This fix also corrects the SPR 25317. |
Note: For SPR 26402
- This is a SDIO patch and needs to be installed with Latest Fusion(37R or onwards).
- Prior to installation, ensure that you are currently running an approved version of the Operating System from the table below. Otherwise, visit https://www.zebra.com/us/en/support-downloads/software/operating-system/mc55a0-and-mc55-hc-operating-system.html and load the correct DCP for your product. This installation contains DHCP.dll which includes DHCP client having fixes for few SPRs. This is required if this cab is installed on any older OEM version.
This HotFix CFE package
CFE_MC55_A0_WM_044710_EN_v010300_e_WB.cab/CFE_MC55_A0_WM_044710_EN_v010300_e_NB.cab obsoletes the following HotFix CFEs:
HotFix CFE version |
---|
CFE_MC55_A0_WM_044710_EN_v010100_e_WB.cab CFE_MC55_A0_WM_044710_EN_v010100_e_NB.cab |
CFE_MC55_A0_WM_044710_EN_v010200_e_WB.cab CFE_MC55_A0_WM_044710_EN_v010200_e_NB.cab |
Note: Latest CFE package includes previous CFE package hot fixes and new SPR hot fix.
Package Details
CFE_MC55_A0_WM_044710_EN_v010300_e_WB.cab (CFE package with auto Warm boot)
CFE_MC55_A0_WM_044710_EN_v010300_e_NB.cab (CFE package without auto Warm boot)
Device Compatibility
This HotFix CFE Package software release has been approved for use with the following Zebra devices.
Device | Operating System | BSP Version |
---|---|---|
MC55A0 |
WM6.5 |
v03.47.04 / v04.47.10 |
Installation Requirements
The HotFix CFE cab can be deployed to the Mobile device through any one of the below mentioned methods. For installing the cab, the users should have at least one of the below mentioned tools.
- Windows Mobile Device Center (For Windows Desktops)
- SD Cards / Micro SD cards
- MDM Set up
Installation Instructions
- Windows Mobile Device Center (For Windows Desktops) Installation Instructions:
1. Copy "CFE_MC55_A0_WM_044710_EN_v010300_e_WB.cab" file to the Application folder on the device.
2. Deploy the solution by tapping on the "CFE_MC55_A0_WM_044710_EN_v010300_e_WB.cab" file.
3. After successful deployment of the "CFE_MC55_A0_WM_044710_EN_v010300_e_WB.cab" file, device will do an automatic warm boot.
- SD Cards / Micro SD cards Installation Instructions:
1. Copy "CFE_MC55_A0_WM_044710_EN_v010300_e_WB.cab" file to the SD card.
2. Deploy the solution by tapping on the "CFE_MC55_A0_WM_044710_EN_v010300_e_WB.cab"
3. After successful deployment of the "CFE_MC55_A0_WM_044710_EN_v010300_e_WB.cab" file, device will do an automatic warm boot.
For MSP or REMOTE installation of the PATCH:
1. Set up MDM (MSP, Soti, Airwatch, etc..) to send "CFE_MC55_A0_WM_044710_EN_v010300_e_NB.cab" file to the application folder of the device.
2. To deploy the solution, setup in MDM to install the cab file "CFE_MC55_A0_WM_044710_EN_v010300_e_NB.cab" file.
3. Changes will take effect after a manual reboot of the terminal or if MDM reboots device.
Release Date
December, 2016