ZT510 / ZT600 Label Calibration Issues

Article ID: 11304773

Issue / Question

Symptoms – Inconsistent media calibration

Applicable To

Affected Printers: ZT510, ZT610, ZT620

Resolution / Answer

Symptoms – Inconsistent media calibration

 
IF Firmware Version is V80.20.9Z OR LOWER:
In the printer menu, select SENSORS -> SELF ADJUST SENSOR, and set to OFF.
This can also be set by sending the following SGD:
! U1 setvar "sensor.self_adjusting_enable" "no"
 
 
If Firmware Version is V80.20.10Z:
Send the following command to the printer:
! U1 setvar "sensor.self_adjusting_enable" "no"
 
 
Another way to test whether the Self Adjust Sensor is still enabled is print out a sensor profile. If enabled, the output will show lines for OUT, WEB, MEDIA, REF, and LBL. The sensor profile with the Self Adjust Sensor set to OFF/NO will only show OUT, WEB, and MEDIA. The below image shows the sensor profile when enabled:



See link for details on running Sensor Profile.
 
 