Code 128 interpretation line is not centered when using an alternate font in ZPL

Article ID: 87444670

Details


 

Topic or Information

Code 128 Interpretation Line is not in the middle of the Barcode when a custom font or size is entered in the ZPL script.

Applies To

Printing a Code 128 Barcode Interpretation Line using an assigned font in ZPL
Excludes: 2824 Series, 2844 Series, S4M (E53 Firmware Version), 888 DD/TT Series, MZ Series, ZQ110, EM220, EM220II

Details

Users have an option to assign an alternate Interpretation Line Font when using ZPL to print a Code 128 Barcode. The Interpretation Line will be left justified and cannot be manually centered on the barcode. 

User-added image

Resolution:

The only option is to use the standard barcode interpretation line if automatic centering is required.

If the standard interpretation line is not acceptable a separate text field will need to be created. This will require manual positioning and entry of all content expected to be viewed including the check digit.