Reprogramming TC8000 PTT key for use in Velocity

Article ID: 00959559

Issue / Question

How can you reprogram the second trigger key, PTT, for Velocity as an Enter key

Applicable To

TC8000, MC92N0, MC32N0, WT6000, TC70, TC75, TC51, TC52, TC56, TC57

Resolution / Answer

Step 1.

Device side remap of hardware key to something velocity can use:
Android Settings > Key Programmer - Change "Grip_Trigger_2" to "Star"

Step 2.
Velocity Console edit to add programmatic key remap to project:
Velocity Project that contains correct Host info - Create Script - Key Replace = 002A > 000A

*000A is Enter in 5250 Host type
*000D is Enter for VT host type

Step 3.
Tap Deploy button to create the .wldep project deployment file.
Add new .wldep file to device Internal storage\com.wavelink.velocity folder to get this added to the Velocity client host list.
*Please remove any previous host that is similar to this one so there is no duplicates.

+ Applicable Products

  • MC3200 Mobile Computer
  • MC9200 Mobile Computer
  • TC51
  • TC52 Touch Computer
  • TC56
  • TC57 Touch Computer
  • TC70
  • TC75
  • TC8000
  • WT6000 Wearable Terminal