Article ID: 50835230

Question


 

Why does the LS3408 Continually Perform a Power on Reset When Attached to VRC6946 while in WaveLink?

Answer


 

When the Wavelink Client responds to commands from the host to the VRC6946, power to the scanner port drops and then is reapplied.  The LS3408 scanner responds by performing a power on reset signaled by 3 beeps (lo, medium, hi).
Answer
To resolve this issue, parameter AllowScanAhead needs to be set to YES in the Wavelink Client.