How Do I Calibrate the Touch Screen on a VRC8946 Using the Stylus?

Article ID: 91925199

Question

How Do I Calibrate the Touch Screen on a VRC8946 Using the Stylus?

Facts

When the touch screen on a VRC8946 is not properly aligned, it may be calibrated using the stylus. VRC8946

Answer

Follow the steps below to calibrate the VRC8946 touch screen:
  1. If you are using the default registry, go to step 5.  Otherwise, proceed with step 2.
  2. Tap the Start menu.
  3. Tap Settings, then Control Panel.  The Control Panel screen will be displayed:
  4. Double tap the Stylus icon.  The Stylus Properties screen will be displayed:
  5. Select the Calibration tab and tap the Recalibrate button.  The Calibration screen will be displayed:
  6. As the screen instructs, carefully press and briefly hold the stylus on the center of each target that appears on the screen. Repeat as the target moves around the screen.
  7. Tap the screen to accept the new calibration.