RTC Real Time Clock not reporting time or date
Article ID: 74126948
Topic or Information QL+ RW Real Time Clock functionality Applies To QL Plus and RW Series Mobile Printers Details In order to utilize the real time clock for the QL+ printers or RW printers Real Time Clock, the time and date need to be initially sent to the printer. The time can be set with the SET-TIME command. Example: ! U1 SET-TIME 08:31:00 or ! U1 setvar "rtc.time" "08:31:00" The date can be set with the SET-DATE command. Example: ! U1 SET-DATE 04-29-2006 or ! U1 setvar "rtc.date" "04-29-2006" Please note that there is no battery backup for the clock. If one removes the battery, the time will need to be reset. |