What Are the Wand Pinouts for the PTC860 Handheld?

Article ID: 07085376

Question

What Are the Wand Pinouts for the PTC860 Handheld?

Facts

PTC860

Answer

The RJ-41 wand connector is provided in all PTC860 models except the PTC860IM, where optional wands and scanners are connected though the DB-25 I/O connector.  Pinouts are listed in the table below (except for PTC860IM):
  • PEN_EN_PWR - Turns on the scanner circuitry.
  • WAND_IN - Indicates incoming data, SOS indicates the start of scan.
  • LSD_TRIG - Indicates that the trigger has been pulled.